NICO probe

Online and in-situ measurements of nitrates

Spectromètre immergeable NICO

NICO is a UV submersible photometer for the online measurement of nitrate NO₃ or total nitragen NOx concentrations.

The probe is equipped with three detection channels for an accurate optical determination of the nitrate by absorption, taking into account the turbidity and organic substances present in the field.

Indeed the reliability of the measurements is enhanced by 3 attenuation measures, the one from nitrate absorption and nitrites at 212 nm, organic compounds at 254 nm and the turbidity measured at 360 nm. Absorption calculations are optimized by a reference photodiode which measures the intensity of the light source and automatically corrects the aging of the lamp.

In case of high nitrite concentrations, a spectral measurement to dissociate nitrates from nitrite is recommended with the OPUS sensor.

The sensor has many accessories to optimize its integration into the processes, automate its cleaning and facilitate the use of mea- surement data. Measurement campaigns and mobile apps are also available with the optional battery.

I'm interested

Measurement principle

A xenon flash lamp emits a broad spectrum light, controlled by a reference diode and directed into a beam of parallel wavelengths toward the optical path to traverse the field. The compounds present in the water then absorb the light at specific wavelengths.
The NICO probe receives the attenuated light and measures on 3 channels the absorption at 212 nm (for the total nitrogen), at 254 nm (light absorbed by the organic compounds) and at 360 nm for the attenuation due to the turbidity .
NICO calculates 212 nm light attenuation, based on organic compounds and water turbidity, to determine the total NOx-N nitrogen concentration of the water.

Applications

  • Wastewater treatment plants
  • Environmental monitoring
  • Drinking water monitoring
  • Industrial applications

Advantages

  • Accuracy and reliability by measurement of attenuation
  • Automatic compensation of turbidity and organic parameters
  • Optical windows with nano treatment against deposits
  • Many accessories for integration
  • In-situ and continuous measurements
Principle of measurementLight attenuation measurement with compensation
Detector4 photodiodes + filters
ParametersNO₃-N, NO₃, NOx-N (calibrated with NO₃ solution standard)
Measuring ranges - 1 mm optical path : 0.5 ... 60 mg / l NO₃-N
Measurement accuracy± 5 %
Turbidity compensationAutomatic
Internat memory2 GB
T100 response time20 s
Measurement interval≧ 10 min
Probe Body MaterialsStainless steel (1.4571 / 1.4404) or titanium (3.7035)
Dimensions (L x d)470 mm x 48 mm (with optical path 10 mm)
Weight~ 3 kg stainless steel
~ 2 kg titanium
Digital output- Ethernet (TCP/IP)
- RS-232 ou RS-485 (Modbus RTU)
Analog output4 ... 20 mA
Power Supply and consumption12 ... 24 VCC, ≦ 8 W
Maintenance≦ 0,5 h/months
Calibration interval24 months
Maximum pressure of use- with SubConn connector : 30 bars
- with fixed cable : 3 bars
- in flowcell : 1 bar
Temperature of the medium / sample+ 2 ... + 40 °C
Inflow velocity0,1 ... 10 m/s